The company specializes in supplying Elisa kits, quality assurance, price concessions, and can provide free testing services, please call to consult!
This manual is for reference only, subject to the company's current provision, please call to obtain it. This kit can only be used for scientific research, not for medical diagnosis.
Goat Interleukin 10 (IL-10) Quantitative Detection Kit (ELISA)
user's Guide
ã€Goat Interleukin 10 (IL-10) ELISA kit kit name】
Goat Interleukin 10 (IL-10) Quantitative Detection Kit (ELISA)
[Goat Interleukin 10 (IL-10) ELISA kit kit use]
Quantitative detection of serum, plasma and related fluids.
ã€Reagents and equipment not required by goat IL-10 ELISA kit】
1. 37 ℃ thermostat
2. Standard specification microplate reader
3. Precision pipettes and disposable tips
4. Distilled water
5. Disposable test tubes
6. Absorbent paper
ã€Composition of goat IL-10 (IL-10) ELISA kit kit】
1
Enzyme coated plate
12 holes × 8
7
Developer A liquid
6mL
2
Standard
0.3mL × 6 tubes
8
Developer B liquid
6mL
3
20 times concentrated washing liquid
25mL
9
Stop solution
6mL
4
Sample diluent
6mL
10
Instructions
1 serving
5
Special diluent
6mL
11
Sealing film
2 sheets
6
Enzyme reagent
6mL
12
sealed bag
1
[Goat Interleukin 10 (IL-10) ELISA kit detection principle]
This kit uses double-antibody two-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the standard and the test sample to the pre-coated goat interleukin 10 (IL-10) monoclonal antibody transparent enzyme label coated plate. After incubation for a sufficient time, wash to remove unbound components, and then add the working solution After sufficient incubation time, wash to remove unbound components. Substrates A and B were added in sequence, and the substrate (TMB) was converted into a blue product catalyzed by horseradish peroxidase (HRP), which turned yellow under the action of an acid. IL-10) The concentration was positively correlated. The OD value was measured at a wavelength of 450 nm. Based on the OD value of the standard and the sample, the goat interleukin 10 (IL-10) content in the sample was calculated.
ã€Steps of goat interleukin 10 (IL-10) ELISA kit】
1. Preparation: Remove the reagent kit from the refrigerator and re-equilibrate at room temperature for 30 minutes.
2. Mixing solution: dilute the 20-fold concentrated washing solution with distilled water to the original one.
3. Add standard products and samples to be tested: take a sufficient number of enzyme-coated plates and fix them to the frame. Set up standard wells, sample wells to be tested and blank control wells, record the positions of each well in the standard wells. Add 50μL of standard product; first add 10μL of sample to be tested, and then add 40μL of sample diluent (that is, the sample is diluted 5 times); blank control well is not added.
4. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.
5. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with the washing solution, let stand for 1min, shake off the washing solution, pat dry on the absorbent paper, repeat the washing 4 times (you can also use the washing machine to press Instructions for washing the board).
6. Add enzyme-labeled working solution: add 50μL of enzyme-labeled working solution to each well, without adding blank control wells.
7. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.
8. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the plate washing 4 times (you can also use the washing machine to press Instructions for washing the board).
9. Color development: add 50μL of developer A solution to each well, and then add 50μL of developer B solution, mix for 30s with a plate mixer (or gently shake for 30s by hand), and avoid color development at 37 ℃ for 15min .
10. Termination: Remove the enzyme labeling plate and add 50μL of stop solution to each well to stop the reaction (the color changes from blue to yellow)
11. Determination: Zero the blank holes, and within 15 minutes after termination, measure the absorbance (OD value) of each well with a wavelength of 450 nm.
12. Calculation: According to the concentration of the standard product and the corresponding OD value, calculate the linear regression equation of the standard curve, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. You can also use various application software to Calculation. The final concentration is the actual measured concentration times the dilution factor.
[Sample requirements for goat interleukin 10 (IL-10) ELISA kit]
1. The sample cannot contain sodium azide (NaN3) because sodium azide (NaN3) is an inhibitor of horseradish peroxidase (HRP).
2. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.
3. The sample should be fully centrifuged, without hemolysis and particles.
ã€Precautions for goat IL-10 (IL-10) ELISA kit】
1. The experiment is carried out in strict accordance with the instructions, and the result of the experiment must be determined by the reading of the microplate reader.
2. If the enzyme-labeled coated board is not used up after opening, it should be put into a sealed bag and added with desiccant immediately.
3. It is recommended that all standards, samples and blank controls be tested in duplicate, and the average value is taken to reduce the experimental error.
4. Keep in mind that the sample has been diluted 5 times. The calculation result is multiplied by 5 to obtain the actual concentration of the sample.
5. The quantitative range of this kit is 6.25-200ng / L. If it exceeds this range, it is calculated from the extension of the standard curve. It is not used for accurate quantitative results. ), Multiplied by the total dilution factor is the final concentration of the sample.
6. If the color is too light, the substrate incubation time can be extended properly.
7. In order to avoid cross-contamination, the tips, samples and blank controls should be replaced with a new one for each addition; the common components such as enzyme working solution, sample diluent and substrate should be cantilevered, and they should not touch the microwells. ; Do not reuse the sealing film.
8. The kits are used within the warranty period, and different batches of reagents should not be mixed.
9. Substrate B is sensitive to light and avoid prolonged exposure to light.
[Summary of the operation procedure of goat interleukin 10 (IL-10) ELISA kit]
Prepare reagents, samples and standards
Add prepared samples and standards, and react at 37 ℃ for 30 minutes
Wash the plate 4 times, add the enzyme reagent, and react at 37 ℃ for 30 minutes
Wash the plate 4 times, add color developing solutions A and B, and develop at 37 ℃ for 15 minutes
Add stop solution
Read OD value within 15 minutes
Calculation
[Goat Interleukin 10 (IL-10) ELISA kit detection range]
Please inquire
ã€Specification of goat interleukin 10 (IL-10) ELISA kit】
96 servings / box 48 servings / box
ã€Storage of Goat Interleukin 10 (IL-10) ELISA Kit】
Store at 2-8 ℃, protected from light and moisture.
ã€Goat Interleukin 10 (IL-10) ELISA Kit Validity Period】
6 months
Filbert Paint Brush is one type of paint brushes. Paint brushes are differents shapes like round , line , Filbert Paint Brush and so on. Our Samina foram brush is made by Synthetic Paint Brush and Nature Hair Paint brush.
Types of brushes
There are so many many brushes:washes/glazes, rounds, flats, filberts and liners and more. Choosing the right type for the technique is important. Let`s look at the different types.
Flat Brushes
Flats are brushes with a straight chisel edge and square shaped filaments. These can be known as shades if they`re in smaller sizes and washes/glazes if in bigger sizes. Large areas are painted with a wash/glaze brush whereas smaller flats are used for small areas of painting
Round brushes
Round brushes have a large diameter of the ferrule, more so than a liner, which can be used for applying thick to thin lines, filling in odd shaped areas, painting details and work great for lettering. Liners don`t hold as much paint as a round, however, they are super great for creating lines or curves. Script liners are similar to liners but the filaments are much longer and hold more paint. A round brush tapers to a pointed tip – several types of rounds are referred to rounds, liners or script liners. Angle brushes are filaments that have been cut on an angle – these are excellent to use in small or curved areas of the painting.
Filberts
Brushes with oval shaped filaments are known as filberts in smaller sizes and oval wash in larger sizes. Both shapes can be used for base coating, stroke work and more. There are filbert combs, filbert wash and more.
Mop Brushes
Then there are mop brushes–great for blending and smoothing out small areas. They`re also ideal for applying powdered pigments–just dust them lightly over hot or tacky wax.
Specialty Brushes
Then there are all the speciality brushes on the market used for certain techniques and garner their own results–fan, deer-foot, stumbler, mops,stencil and more
Filbert Paint Brush, Paint Brushes Art set , Paint Brushes, Synthetic Paint Brushes, Nylon Paint Brushes
SAMINA FORAM (SHENZHEN) CO., LIMITED. , https://www.saminabrush.com