DDMX—100 pulse instrument of traditional Chinese medicine

DDMX-100 pulse instrument is mainly used for noninvasive pulse detection. The transducer can be placed in any one of the radial artery inch, close and ruler according to the need to detect pulse information.

It has a remarkable feature of low power consumption and no external power supply. Connect to the computer through the USB interface to obtain power. It is easy to carry and adapts to work outdoors without power supply.

The pulse instrument consists of a single-head pulse transducer, pulse amplifier, A / D conversion card, computer (user-supplied) and pulse dialectic analysis software. It can automatically collect pulse signal, and automatically analyze and process the characteristic parameters of the position, number, shape, potential and pulse of the pulse of TCM.

Function: This instrument uses traditional Chinese medicine pulse detection, can display and store digitized pulse signal in real time, automatically identify the position, number, shape, and potential of the pulse to identify the characteristics of the pulse chart, and can display a series of pulse charts, the best pulse chart and its characteristics Parameters, pulse pressure-pulse amplitude trend chart, 40 seconds (S) pulse wave trend chart, pulse measurement conclusion, and print pulse chart detection report.

Uses: This instrument is an intelligent instrument for traditional Chinese medicine clinical detection and basic experimental teaching. It can be widely used in experimental teaching of traditional Chinese medicine diagnosis, as well as clinical auxiliary diagnosis, condition monitoring, traditional Chinese medicine, acupuncture, qigong, rehabilitation, health care measures of various traditional Chinese medicine departments. The evaluation of curative effect provides reliable objective indicators for teaching, scientific research and clinical practice. This instrument also has good application prospects in computer network remote teaching and remote diagnosis.

Main Specifications:

Transducer sensitivity: 0.5mv / gram force (bridge voltage 5V)

Transducer linear range: 0-250 grams of force

AC amplifier circuit (pulse wave circuit):

Input dynamic range: 0-25mV (0-50gf, dynamic force)

Full-scale output: 4.5V

Time constant: greater than 3 seconds

DC amplification circuit (pulse pressure circuit):

Input dynamic range: 0-125mV (equivalent to 0-250 grams force, static force)

8-channel 12-bit A / D conversion

The software system is suitable for WINDOWS2000 / XP operating system.